HVAC SYSTEM BALANCING CHECKLIST (FOR OPTIMAL EFFICIENCY) Created by ChecklistGuro (https://checklistguro.com) --- PRE-BALANCING ASSESSMENT & PLANNING --- [ ] Date of Assessment [ ] Time of Assessment Start [ ] Brief Description of HVAC System (Type, Age, Capacity) [ ] Building Square Footage [ ] System Configuration (e.g., VAV, Constant Volume, etc.) (VAV, Constant Volume, VRF, Other - Specify in Long Text) [ ] Existing HVAC System Drawings/Schematics (if available) [ ] Review of Previous Balancing Reports (if available - summarize findings) [ ] Primary Balancing Goals (Select all that apply) (Energy Savings, Improved Comfort, Noise Reduction, Addressing Specific Complaints) [ ] Notes/Observations Prior to Balancing (e.g., noted airflow issues, complaints) --- AIRFLOW BALANCING --- [ ] Measured Airflow (CFM) at Supply Diffuser 1 [ ] Design Airflow (CFM) for Supply Diffuser 1 [ ] Damper Adjustment Needed at Supply Diffuser 1? (Yes, No) [ ] Damper Adjustment (Percentage) for Supply Diffuser 1 [ ] Measured Airflow (CFM) at Return Grill 1 [ ] Notes on Airflow Balancing at Supply Diffuser 1 [ ] Areas experiencing airflow issues? (Too Cold, Too Warm, Drafty, Uneven Temperature, None) [ ] Adjusted Zone Temperature Setpoint? (Yes, No) --- HYDRONIC SYSTEM BALANCING (IF APPLICABLE) --- [ ] Initial System Water Temperature (Supply) [ ] Initial System Water Temperature (Return) [ ] System Flow Rate (GPM) [ ] System Pressure (PSI) [ ] Valve Type (e.g., Balancing Valve, Control Valve) (Balancing Valve, Control Valve, Butterfly Valve, Other - Specify) [ ] Valve Adjustment (Position/Percentage) [ ] Notes on Valve Adjustment and Reason [ ] Bypass Valve Status (Open/Closed) (Open, Closed) [ ] Differential Pressure Across Balancing Valve (PSI) --- STATIC PRESSURE VERIFICATION --- [ ] Total Supply Air Volume (CFM) [ ] Design Static Pressure (inches of water) [ ] Measured Static Pressure at Main Supply Plenum (inches of water) [ ] Measured Static Pressure at Fan Discharge (inches of water) [ ] Measured Static Pressure at Farthest Supply Diffuser (inches of water) [ ] Fan Speed (RPM) [ ] Fan Speed Adjustment Necessary? (Yes, No) [ ] Notes on Static Pressure Adjustments & Observations [ ] VAV Box Static Pressure Sensor Calibration Required? (Yes, No) --- EQUIPMENT PERFORMANCE CHECKS --- [ ] Supply Fan RPM (Revolutions Per Minute) [ ] Return Fan RPM (Revolutions Per Minute) [ ] Supply Air Temperature (°F) [ ] Return Air Temperature (°F) [ ] Chilled Water Supply Temperature (°F) [ ] Chilled Water Return Temperature (°F) [ ] Hot Water Supply Temperature (°F) (if applicable) [ ] Hot Water Return Temperature (°F) (if applicable) [ ] Supply Fan Motor Condition (Visual Inspection) (Excellent, Good, Fair, Poor) --- DOCUMENTATION & REPORTING --- [ ] Balancing Report Summary [ ] Total System Airflow (CFM/m³/h) [ ] Total System Water Flow (GPM/LPM) - if applicable [ ] As-Built HVAC Drawings (Updated) [ ] Overall Balancing Success (Subjective) (Excellent, Good, Acceptable, Poor) [ ] Balancing Completion Date [ ] Recommendations for Future Maintenance [ ] Balancing Technician Signature [ ] Project Name/Location --- POST-BALANCING VERIFICATION --- [ ] Date of Post-Balancing Verification [ ] Time of Post-Balancing Verification [ ] Static Pressure (in) [ ] Supply Air Temperature (°F) [ ] Return Air Temperature (°F) [ ] System Stability (after 24 hours) (Stable, Minor Fluctuations, Significant Fluctuations - Further Adjustment Needed) [ ] Notes on Post-Balancing Observations [ ] Overall System Performance (compared to baseline) (Improved, Maintained, Decreased) --- END OF TEMPLATE --- Transform this text into a digital, automated, and trackable mobile app! Visit: https://checklistguro.com/templates/facility-management/hvac-system-balancing-checklist-for-optimal-efficiency (Click "Install Template" to launch your digital inspection tool immediately)