RAISED FLOOR INSPECTION & CLEANING Created by ChecklistGuro (https://checklistguro.com) --- PRE-INSPECTION & SAFETY --- [ ] Inspection Date [ ] Inspection Start Time [ ] Raised Floor Location (Area/Room) [ ] Brief Description of Area/Purpose [ ] PPE Required (Check all that apply) (Safety Glasses, Gloves, Dust Mask/Respirator, Hearing Protection, Steel-Toe Boots) [ ] Any known hazards or previous issues? [ ] Ambient Temperature (°C/°F) [ ] Inspector Name --- VISUAL INSPECTION - FLOOR TILES & PANELS --- [ ] Tile Condition - Cracks/Fractures (None, Minor (Surface), Moderate (Partial), Severe (Through)) [ ] Tile Condition - Loose/Wobbly (None, Few (<5), Moderate (5-10), Many (>10)) [ ] Number of Tiles Requiring Replacement [ ] Tile Fastening Type (Screws, Retaining Clips, Other (Specify)) [ ] Detailed Notes on Tile Damage (if any) [ ] Tile Material (Carpet, Vinyl, Steel, Other (specify)) [ ] Evidence of Water Damage? (No, Minor Staining, Visible Corrosion, Active Leak Detected) --- PEDESTAL & CABLE MANAGEMENT INSPECTION --- [ ] Pedestal Condition (Good, Minor Damage (scratches, chips), Significant Damage (broken panels, loose components), Missing Pedestals, Other (specify in LONG_TEXT)) [ ] Pedestal Condition Details (if 'Other' selected) [ ] Number of Pedestals Inspected [ ] Cable Routing Adequacy (Optimal - Organized and clearly labeled, Adequate - Generally well-managed, Suboptimal - Overcrowded and/or unlabeled, Poor - Significant cable management issues) [ ] Cable Management Notes [ ] Cable Labeling Status (All Cables Clearly Labeled, Most Cables Labeled, Some Cables Labeled, No Cables Labeled) [ ] Specific Location of Cable Management Issues --- UNDER-FLOOR SPACE INSPECTION --- [ ] Overall Impression of Under-Floor Space [ ] Presence of Debris (Select all that apply) (Dust/Lint, Rodent Droppings, Insect Infestation, Water Leaks/Moisture, Construction Debris, Other (Specify)) [ ] Measured Humidity (%) [ ] Evidence of Water Leaks (If Any) [ ] Cable Management Condition (Excellent - Well Organized, Good - Minor Issues, Fair - Requires Attention, Poor - Significant Issues) [ ] Photograph of Under-Floor Space (General) [ ] Any Unusual Odors Detected? --- CLEANING - TILE/PANEL SURFACE --- [ ] Cleaning Method Used? (Vacuuming, Damp Mopping, Dry Mopping, Specialized Cleaning (Specify in LONG_TEXT)) [ ] If Specialized Cleaning, please describe method and chemicals used: [ ] Quantity of Cleaning Solution Used (Liters/Gallons): [ ] Tile Surface Condition After Cleaning? (Excellent - No residue or streaks, Good - Minor residue or streaks, Fair - Noticeable residue or streaks, Poor - Significant residue or streaks) [ ] Areas requiring additional attention (check all that apply): (Stain Removal, Edge Cleaning, Around Pedestals, None) [ ] Detailed notes on any stains or problem areas encountered during cleaning: --- CLEANING - UNDER-FLOOR PLENUM --- [ ] Describe current condition of underfloor plenum (dust, debris, obstructions) [ ] Identify debris found in the plenum (select all that apply) (Dust, Cobwebs, Rodent droppings, Insect nests, Loose cables, Debris - General, Water Stains/Evidence of Leakage) [ ] Approximate Dust Depth (in inches) [ ] Describe method used for plenum cleaning (e.g., vacuuming, compressed air) [ ] Attach photographs of the underfloor plenum (pre-cleaning) [ ] Note any unusual odors detected during cleaning. [ ] Attach photographs of the underfloor plenum (post-cleaning) --- POST-CLEANING & DOCUMENTATION --- [ ] Date of Inspection & Cleaning [ ] Start Time [ ] End Time [ ] Summary of Findings & Actions Taken [ ] Quantity of Tiles/Panels Inspected (optional) [ ] Areas/Sections Cleaned (Select all that apply) (Section A, Section B, Section C, Entire Raised Floor) [ ] Overall Condition After Cleaning (Subjective) (Excellent, Good, Fair, Poor) [ ] Photos of Post-Cleaning Condition (Optional) [ ] Inspector Name [ ] Inspector Signature --- END OF TEMPLATE --- Transform this text into a digital, automated, and trackable mobile app! Visit: https://checklistguro.com/templates/facility-management/raised-floor-inspection-cleaning (Click "Install Template" to launch your digital inspection tool immediately)