WELDING FUME EXTRACTION SYSTEM CHECKLIST Created by ChecklistGuro (https://checklistguro.com) --- SYSTEM OVERVIEW & LOCATION --- [ ] System Location (Primary Welding Area) [ ] System Identification Number/Tag [ ] Manufacturer [ ] Model Number [ ] Date of Last Major Service [ ] Date of System Installation [ ] Current System Operational Status (0=Offline, 1=Online) [ ] Brief Description of System Configuration & Purpose --- LOCAL EXHAUST VENTILATION (LEV) HOODS & CAPTURE --- [ ] Hood Location(s) Inspected [ ] Hood Condition - General (Excellent, Good, Fair, Poor, N/A) [ ] Estimated Distance from Hood to Welding Process (inches) [ ] Hood Material Condition (No Damage, Minor Damage, Significant Damage, Corrosion Present) [ ] Hood Obstructions? (None, Welding Curtains, Equipment, Debris, Other (specify in LONG_TEXT)) [ ] If 'Other' selected above, please specify [ ] Airflow Appearance - Adequate Capture? (Yes, No, Uncertain) [ ] Describe any observed capture deficiencies (if 'No' or 'Uncertain' selected above) --- DUCTWORK & CONNECTIONS --- [ ] Ductwork Segment Identification - Start Point [ ] Ductwork Segment Identification - End Point [ ] Visual Inspection - Ductwork Condition (Excellent - No visible damage, Good - Minor surface corrosion, Fair - Moderate corrosion/damage, Poor - Significant damage/leakage) [ ] Ductwork Temperature (Celsius) [ ] Connection Type (e.g., Flanged, Clamped) (Flanged, Clamped, Welded, Other) [ ] Connection Leakage Assessment (No Leakage, Minor Leakage, Moderate Leakage, Significant Leakage) [ ] Detailed Observations / Notes regarding Ductwork and Connections [ ] Photographic Evidence of Ductwork/Connections (if necessary) --- FILTER SYSTEM --- [ ] Initial Filter Pressure Drop (in H2O) [ ] Current Filter Pressure Drop (in H2O) [ ] Filter Media Type (HEPA, Pleated, Cartridge, Other (Specify)) [ ] Comments on Filter Condition (Appearance, Damage, etc.) [ ] Last Filter Replacement Date [ ] Estimated Remaining Filter Life (in hours/days) [ ] Filter Inspection Findings (Clean, Slightly Soiled, Moderately Soiled, Heavily Soiled, Damage Present, No Visible Issues) [ ] Filter System Photos (Optional) --- FAN & MOTOR --- [ ] Fan RPM (Revolutions Per Minute) [ ] Motor Amperage (Current Draw) [ ] Fan Static Pressure (in H2O) [ ] Motor Lubrication Status (Lubricated as per schedule, Lubrication needed, Not Applicable - Sealed Motor) [ ] Motor Sound Level (Normal, Slightly elevated, Excessive - Investigate) [ ] Notes on Motor and Fan Condition [ ] Last Lubrication Date (if applicable) --- EXHAUST DISCHARGE & AIRFLOW --- [ ] Exact Location of Exhaust Discharge Point [ ] Airflow Velocity (m/s or ft/min) at Discharge [ ] Static Pressure at Fan Inlet (Pa or in.wg) [ ] Discharge Location Complies with Regulations? (Yes, No, N/A - Local Regulation Not Applicable) [ ] Observations regarding potential re-entrainment or nearby sensitive areas [ ] Is exhaust directed away from building intakes? (Yes, No, N/A - No Building Intakes Nearby) [ ] Differential Pressure Across Filter (Pa or in.wg) --- SYSTEM MONITORING & ALARMS --- [ ] Airflow Reading (CFM/m³/min) [ ] Static Pressure Reading (in. w.g / Pa) [ ] Alarm Status - Filter Pressure (Normal, Warning, Alarm) [ ] Alarm Status - Airflow (Normal, Warning, Alarm) [ ] Last Alarm Reset Date [ ] Alarm History - Summary of Recent Events (last 30 days) [ ] Current System Operating Mode (Automatic, Manual, Standby) [ ] Time of Last System Interruption --- MAINTENANCE RECORDS & DOCUMENTATION --- [ ] Last Filter Replacement Date [ ] Filter Replacement Pressure Drop (inches of water) [ ] Description of any maintenance performed since last inspection [ ] Date of Last System Performance Test [ ] Airflow Measurement (CFM) at Exhaust [ ] Filter Type (HEPA, Pleated, Baghouse, Other) [ ] Upload any relevant maintenance reports [ ] Notes/Comments on maintenance performed and system condition [ ] System Operational Training for Personnel Complete? (Yes, No, N/A) --- SAFETY & EMERGENCY PROCEDURES --- [ ] Date of Last Emergency Drill Related to Fume Extraction Failure [ ] Describe the procedure to follow if the fume extraction system fails during welding operations. [ ] Is there a documented procedure for isolating welding operations during system maintenance? (Yes, No, N/A) [ ] Which personnel are trained on emergency shutdown procedures? (Welding Technicians, Facility Management Staff, Safety Officer, Maintenance Personnel, Other (Specify in Long Text)) [ ] Date of last review of emergency procedures. [ ] Describe the communication protocol used to notify personnel of a system failure. [ ] Are emergency contact numbers readily available near welding stations? (Yes, No, N/A) [ ] Estimated time required to restore system after failure (typically). --- END OF TEMPLATE --- Transform this text into a digital, automated, and trackable mobile app! Visit: https://checklistguro.com/templates/facility-management/welding-fume-extraction-system-checklist (Click "Install Template" to launch your digital inspection tool immediately)